Seismic joint covers are specialized architectural components designed to protect and conceal expansion joints in buildings and structures located in seismically active regions The inadequate seismic resistance and inadequate thermal insulation of older buildings necessitate their retrofitting. This is made evident by powerful earthquakes that cause historic buildings to collapse and sustain damage, leading to financial losses, serious injuries, and fatalities.

Furthermore, the energy consumption of outdated building envelopes is increased due to their low energy performance. The best seismic joint cover is a functional connection between two buildings, seismic joints naturally develop when they are constructed next to each other.

Understanding Seismic Joint Covers

A seismic joint cover produces a separation between the two buildings or parts of buildings this usually results in the separation of walls, floors, and roofs. They may also accommodate the movement of pumping, HVAC ducts, and other components that have.

Seismic joints were not even used as joints in the early applications. They were just identified as the gaps between houses that were next to each other. When structural engineers in seismically active places began to consider the lateral movements of buildings during seismic events.

They developed guidelines for the width of seismic joints, such as two inches per storey. As they examined the destruction caused by earthquakes, they have begun to notice signs of building collisions and occasionally really significant damage.

Sometimes, when the floors of nearby buildings did not line up or one building was significantly taller than the other, especially severe damage occurred. Seismic joints have also frequently been introduced in areas where weak diaphragms are known to

exist and it is deemed preferable to install a joint instead of risk experiencing damage resulting from a potential seismic event.

Structural engineers started to understand that certain building shapes resulted in potentially unwanted effects, such as torsion or high collector forces at reentrant corners.  Their analysis methods were inadequate to deal with as seismic analysis advanced to the level of the static analysis methods of the 1950s and 60s.

Seismic joints were widely used to split a large, intricate building into a collection of smaller, simpler structures with predictable seismic performance and easier to assess. An L-shaped building, for instance, was frequently split into two rectangles.

View the product Floor Expansion Joint Covers

Seismic Joint Cover Systems

when a seismic joint cover is required. These profiles go over the expansion joints that are made in the floor or ceiling to allow structural movements and natural thermal expansion without causing the coating to fracture. Typically, they are aluminum profiles like the Copritec CP or Covertec SP. It is common practice to add seismic joints to individual wings or other sections of a single building

Construction seismic joint coverings aim to give construction joints protection. They offer a tidy solution that accommodates any small movement. Resilient floor coverings can be used with EJC profiles. It should be noted that EJC profiles should not be used over structural expansion joints.

When parts of a structure shift, such as construction joints in concrete slabs, covers are utilized as expansion joint gap covers. Structures shrinking over time, thermal expansion and contraction, and, in certain situations, seismic activity are all factors that buildings are made to accommodate.

The design of seismic joints is complicated and requires work from the entire design team to ensure that the joint is the right size, weather-tight, and safe to walk on. It also involves allowing enough space for other systems to pass over the joint and ways to keep the floor, roof, and wall systems' fire ratings intact.

View the product Control Joint

Seismic Joint Covers: Ensuring Safety and Stability in Earthquake-Prone Areas

Seismic joints protect building components from ruptures, cracks, and possible collapse when both vertical and horizontal movements occur. Similar to a sponge, seismic joints maintain the stability and integrity of the building by absorbing shockwaves.

While expansion joints covers are fundamentally distinct, seismic joints and expansion joints share certain similarities. To handle building movements brought on by creep, shrinkage, or temperature variations, expansion joints were devised. They are frequently one-way joints, meaning that their primary function is to allow motions perpendicular to the joint.

According to the anticipated rate of shrinkage or temperature movement along the building's length, expansion joints are also frequently positioned at regular intervals of length. Seismic joints, on the other hand, are usually independent of building length or size and must support movement in both orthogonal directions simultaneously.

The expansion joints—also known as movement joints, structural joints, isolation joints, control joints, or seismic joints—are the areas of movement over which the coverings are placed. Joints should be used sparingly because they are expensive and unsightly from an architectural standpoint.

See more
best control joint in concrete in 2024

The Role of Seismic Joint Covers in Building Resilience

Seismic joint coverings' function in constructing resilience Depending on the building's stiffness and height. In a contemporary building, the seismic junction width could be anywhere from a few inches to several feet. Joints in modern structures constructed after 1988 are usually much wider than those in comparable structures.

While there are other important variables, the main reason for this is changes in the codes. Additional contributing factors include the fact that many modern buildings have less lateral stiffness and that engineers are more aware of the degree of real lateral deformations. This is an extensive handbook for engineers and architects on seismic joint covers.

Examining the evolution of seismic joint width and drift calculations from the standpoint of code development is enlightening. Based on assumptions for a 10-story Special Steel Moment Frame building on decent soil in a basic Seismic Zone 4 (not near-fault) region, the following table has been created. Calculations are made for two 10-story wings that are identical.

A lot of the time, seismic joints lead to rather complex structural framing situations. Even at the most basic joints, the required structural support is provided by independent columns positioned on opposite sides of the junction. If the structure cannot be supported by double columns, it must either be cantilevered from columns that are placed farther apart or use seated connections.

When it comes to seated connections, there is a tendency to restrict the sliding element's journey since longer sliding surfaces with Teflon sliders or other such devices are more expensive and the seat element might interfere with other building components.

A Comprehensive Guide to Seismic Joint Covers for Architects and Engineers

Seismic joints are despised by architects, and for good reason. Regardless of how effectively they are executed, the joints are an expensive and unsightly aspect of the building that take a great deal of the architect's creative energy. Architects often request that the joints in low- to mid-rise buildings have the same width throughout the building to simplify the design.

Seismic joints are despised by architects, and for good reason. Regardless of how effectively they are executed, the joints are an expensive and unsightly aspect of the building that take a great deal of the architect's creative energy. Architects often request that the joints in low- to mid-rise buildings have the same width throughout the building to simplify the design.

From the standpoint of structural engineering, this is okay, but because larger-than-necessary seismic joint covers will be used at the building's lower floors, this may increase the joint's cost.

See more
seismic joint expansion joint in buildings 2024
Expansion Joint and Control Joint What Is The Difference

Enhancing Structural Integrity with Seismic Joint Covers

An expansion joint is quite important. It performs a crucial role as a protective interface between different construction elements such as floors, walls, and ceilings. It protects the structural integrity by allowing for regulated expansion and contraction, preventing costly problems like fractures, leaks, and gaps.

This crucial element efficiently accounts for the natural movement of construction materials in reaction to various factors such as temperature changes, seismic activity, and wind loads.

View the product Expansion Joint Solutions

Conclusion

Innovating solutions for seismic joint covers in modern construction have been in use for a long time. But as time has gone on, more and more width has been needed, which has increased the expense of the separations.

In the past, engineers have implemented seismic joints within a single building to either streamline analysis or lessen the seismic consequences of construction imperfections. Due to the high expense and unfavorable architectural impact of seismic joints, many structures that once may have included them have had their joints eliminated thanks to the application of sophisticated computer analytical techniques.

When seismic joints are utilized, all members of the design team must provide intricate and meticulous details to guarantee that the specifications for structural function, weather tightness, fire separation, look, and services distribution performance are all satisfied.

What is a seismic joint cover?

Large, complex buildings were frequently divided into a number of smaller, simpler structures with predictable seismic performance that were also easier to evaluate using seismic joints. For example, it was common to divide an L-shaped building into two rectangles.

What is a joint cover?

When two structures or portions of buildings are separated by a seismic joint cover, the walls, floors, and roofs typically separate as a result. They might also allow for the movement of a pump.

View the product Wall & Ceiling Expansion Joint Covers

What is the purpose of the expansion joint cover?

A covered transition over the Expansion Joint opening is provided by an Expansion Joint Cover, or EJC for short. It is unaffected by the relative movement of the two surfaces on either side of the joint.

 

Contact information for Ichemeg



Have any questions, suggestions or complains ?

Message us on whatsapp.

Expansion Joint Solutions

+20 1080029701

Construction Chemicals Solutions

+20 1010042900

Concrete Additives

01010027900

Ceramic Profile and Accessories

01022000050